PB 2000

Power Battery Backup PB 2000

Traffic control Battery Backup from a traffic control company – the logical choice for reliable intersection operation.

Request information

Details

The PB2000-ITS automatically provides emergency back-up power to traffic signals and controls whenever normal electric power is lost.

 

It increases or decreases voltage to maintain normal operation during brownouts and power spikes, reducing the chance of dangerous intersection collisions due to “dark” signals, thus reducing the need for law enforcement and emergency personnel resources.


Using the new web-card, it is easier than ever to connect to the Oriux PB2000 via Ethernet. We now have the ability to setup multiple users and check current status from anywhere using most web browsers.

 

Input

Input

  • Voltage range: 90 to 150 programmable. Default 100 to 130 +/- 2VAC
  • Frequency: 60 +/- 3Hz
  • Maximum Input Current: 30 A (resistive)
  • Inrush Current: Load Dependent
  • Over Current Protection: Double pole single throw circuit breaker rated 30 A for input and output, DC bus 60 A breaker
  • Transient Suppression: MOV Transient suppression elements (>150V)
  • Step Load Response (50% Load Change): ½ Cycle Full Recovery (Full resistive load)
  • Short Circuit Protection: 15 A Circuit Breaker
  • Battery String Voltage: 48 (Four 12VDC Batteries)
Output

Output

  • Apparent Power: 2000VA (inverter mode) and 2000VA (line mode)
  • Active Power, W: 1500 (inverter mode) and 1500 (line mode)
  • Power Factor: 0.075
  • Output Voltage, VAC line and Buck/Boost Mode: 120 nominal, 100-130 +/- 2 VAC (follows input voltage)
  • Inverter Mode: 120 VAC +/- 5%
  • Frequency: 60 +/- 0.4 Hz
  • Transformer: Linear (non-isolated)
  • Output Waveform: Sine Wave
  • Output Waveform THD: <3% (Resistive Load)
  • Load Crest Factor: 3: 1 (Max)
  • Overload Capacity: 110% for 3 min.
Functions

Functions

  • Brownout Protection: Unit boosts output voltage (or transfers to battery) during brownout or low input line conditions and returns to normal when input power stabilizes over user -selected time period. Set points for Transfer / Retransfer, To / From Battery / Boost are users programmable.
  • Generator Compatibility: Generator mode allows wider variation in input voltage and frequency for use with an AC generator
  • Battery Charger 10 A: PFC switch-mode, two-stage charger, temperature compensated (-2 .5 to -5 m V/°C/cell, auto shutoff above 50°C
  • Inverter Mode: Capable of running continuously in inverter mode
  • Inverter Mode Current Limit: Continuous electronic current limit is provided
  • Remote monitoring:
    • Input and output voltages
    • Input line frequency
    • Output power
    • Battery voltage
    • Battery temperature
  • NOTES:
    1. Between 55° and 74°C, the un it is de-rated to a maximum rectified-capacitive load o f 15 00VA / 1,200W
    2. De-rate operating temperature above 4,900 ft (1,500 mts 2°C per each additional 1,0 0 0 ft (30 0m).
Communications

Communications

  • RS-232 / USB / Ethernet Ports: Monitors, controls with terminal emulation software
  • RS-232: DB-9, Female, Opto-Isolated, straight-thru cable
  • USB: B-Ty recepeptacle
  • SNMP (optional): Ethernet, auto-detected 10/100 Mbps
  • Ethernet (optional): Ethernet, auto-detected
  • Display panel: 2-line LCD
Certification and Approvals

Certification and Approvals

  • Electrical Safety: UL-1778, CSA-107.1, UL-1950
  • EMI: FCC Class A
  • Surge Immunity:Tested to: IEC 1000-4-5, IEEE C62.41
Performance

Performance

  • Transfer Time Controller:4 to 10 ms
  • PTS: <30 ms
  • TOTAL:<65 ms
  • Efficiency, Line Mode:>95% (Resistive Load)
  • Efficiency, Inverter Mode:>80% (Resistive Load)
Control Terminal Block

Control Terminal Block

  • Functions:
    1. Provides 6 sets of programmable contacts at pin 1 thru pin 18 for intersection flash control, Remote Alarms, Pagers or other user interface.
    1. “Low Batt": Batteries have reached approximately 40% capacity remaining
    2. "On Batt": Unit is in inverter mode
    3. "Timer”: Unit has been in inverter mode for 2 hours (programmable)
    4. “Alarm”: Any of the following conditions occur: line, frequency error, low output voltage, no temperature probe, overload, no battery connected, high temperature, low temperature
    5. “Fault": any of the following conditions occur: Temperature, low temperature, short circuit, Batt low voltage, Batt high voltage, high temperature, overload.
    1. Provides 48 VDC signal to PTS on pins 21 & 22 C. Triggers self-test by momentarily shorting pin 19 & 20 with less than 100 ohm.
  • Contact Type: Form C. Dry Contacts rated 1 Amp at 240V
  • Wiring: Uses 14-26 AWG
Environmental

Environmental

  • Operating TempºC: -37 to +74°C (See Notes 1 & 2)
  • Storage TempºC: -50 to +75°C
  • Humidity: <95% non-condensing
  • Altitude: 10,000 ft (3000m) (SeeNote 2)
Mechanical

Mechanical

  • Dimensions (WxDxH) inch/mm: 17.5, 19 in x 10.5 in x 5.25 in - 444, 483 mm x 267 mm x 133 mm
  • Weight: 46.2 lb / 21 kg
  • Mounting: 19” (483 mm) rack or shelf mount
  • Input Connection: 3 Position Terminal Block
  • Output Connection to Loads: Two 3 Position Terminal Blocks
  • Cooling: Microprocessor controlled, 12 VDC, 3.6” (92mm) fan
  • Audible Noise Level, dBA: <40
  • MBS/PTS Dimensions (WxDxH) for Standard rack mount: 17.5 in or 19 in with flange x 8.5 in x 3.5 in - 444 mm or 483 mm with flange x 216 mm x 89 mm
  • MBS/ PTS Mounting: Shelf or 19” rack mount
  • MBS/PTS Weight (lb/kg):7.0/3.2
  • MBS/PTS Input Connection: Terminal Block
  • MBS/PTS Output Connection to Loads: Terminal Block
  • MBS/PTS Output connection to UPS: 6 foot cable ready for hard wire to UPS terminal block
  • MBS/PTS cooling: Convection (approx. 7 W contactor coil dissipation)